Pdf veritas r8 installation manual

Pdf veritas r8 installation manual

Installation Veritas 8, 8C & R8 Installation Manual 6 INS 3. Installation Installation Sequence Before attempting to install the alarm system, read this section. Once you have an overall understanding of the installation sequence, carefully work through each step. Mount the control panel on a flat, plumb wall using at least. Veritas R8 Plus & Excel Installation Manual Quick Reference and Factory Settings INS 5 Programming Option Option Code Programming Procedure Factory Setting Zone Disable Suite ’#+ Select Zone Number(s) % to # Press, No Zones Included. INS (veritas eng) INSTALLATION MANUAL Security Control Panels THANK YOU FOR VOTING TEXECOM. Table of Contents 2 INS Table of Contents Section Page 1 Programming Summary 4 Programming Menu 4 Programming Reference Table 5 Installation). Veritas. Installation. Texecom Veritas alarm installation manuals. The following is a full list of the different Texecom Veritas alarm installation manuals, provider installer guides for installing the different Veritas alarm systems – all of which are based around the same core Veritas alarm panel (but importantly there are differences between some of the models, so please check you have the right alarm. Veritas R8 Plus & Excel Installation Manual Quick Reference and Factory Settings INS 5 Programming Option Option Code Programming Procedure Factory Setting Zone Disable Suite 48 Select Zone Number(s) 1 to 8 Press G No Zones Included Zone Soak Test Suite 49 Select Zone Number(s) 1 to 8 Press G No Zones Included Full Set Suite 50 Select Zone Number(s) 1 to 8 Press G All Zones .

Also See for Veritas 8 Installation manual - 32 pages User manual - 8 pages. Page of 44 Go. Show quick links. Hide Hide permanently. Table of Contents. Texecom Veritas 8 User Manual 8 pages.

Pdf veritas r8 installation manual

Security control panels with integrated communicator 24 pages. Security control panels with integrated communicator 80 pages.

Veritas Excel

Page 6: Installation Installation 2 Installation 2. Programming is usually unnecessary as the factory settings section 1. However all functions are fully programmable for Complete Control.

Page 7: Wiring The Control Panel 1 Although the Veritas has been designed for maximum compatibility, for optimum performance, it is highly recommended that the Veritas should be used with Texecom's range of detectors, sounders and batteries. Page 8: Veritas Pcb Layouts Installation 2. Figure 4 - Wiring Magnetic Contacts Figure 4a - Wiring a Single Magnetic Contact to a Zone see also Figure 6 Figure 4b - Wiring Multiple Magnetic Contacts to a Zone see also Figure 6 Mixing powered detectors and magnetic contacts on one zone is easiest if the wiring is taken from the control panel to the powered detectors first.

INSTALLATION MANUAL

Page Powered Detectors Installation 2. Powered detectors are connected to one of the eight terminal pairs labelled Z1 to Z8 on the control panel and are powered from the two terminals labelled AUX on the control panel as follows: Terminal Connect To Suggested Colour Page Extension Speaker s Installation 2.

Pdf veritas r8 installation manual

All the indicator lights will come on. Page Servicing The System Installation 2. A flashing light means action required - mains power can still be present. Page Trouble Shooting Installation 2. Fuses should comply with IEC Using the extended display during Walk Test section 3. If the extended display identifies the fault as bell box tamper, then the cause may either be Bell Tamper or Global System Tamper. Page Programming Programming 3 Programming Programming is usually unnecessary as the factory settings have been carefully selected to suit most installations without alteration.

Page Miscellaneous Selections One Programming 1 Single Button Setting Option 3 allows the system to be set using the keys without the need to first enter a User code. Texecom accept no liability whatsoever for any loss resulting from locked Engineer codes. The zone lights of the options currently selected will illuminate. Page Engineer Reset When an Engineer Reset is required, the zone lights will display a random 4 digit sequence. Each digit will flash in turn and then pause before repeating.

Texecom's Anti-Code software will accept this sequence to generate a 4 digit code which should be entered, after which the system can be reset as normal.

Page Push To Set Programming 3. The user starts full set in the usual way and leaves the premises.

  • Sherlock season 3 download 720p torrents
  • However the system will ONLY set when an external push button is pressed. Page Walk Testing Programming 1 The zone light corresponding to each output will illuminate when it is on. Option will cause the strobe output to pulse 3 times to invoke Hold-Off Mode.

    All the zone lights will turn off.

    Language files 11th edition download

    The system will chime to confirm that all the factory settings have been re-loaded into the Non Volatile Memory. The system will then automatically revert to the Programming Menu and all the zone lights will illuminate. Page 28 Programming Each zone may be programmed with one of these Zone Types which are described in the following sections: 3.

    This Zone Type would typically be used for a front door magnetic contact or, if one is not fitted, a hall PIR. The Final Door Set option section 3.

    Veritas alarm installation manuals

    Page Programming The Date Disclaimer: It is the responsibility of the Installer to obtain prior written agreement from the Customer regarding any use of a Service Timer. Texecom accept no liability whatsoever for any dispute resulting from the use of Service Timers. Service Timer One is designed to be used as a reminder. Page Programming The Suites Programming 3.

    A zone with a double knock attribute must be activated either twice within 10 seconds or once for longer than 10 seconds in order to cause an alarm. To program the Zone Soak Test Suite, enter.

    Texecom Veritas 8 Installation Manual

    The zone lights of the zones currently included in the Zone Soak Test Suite will illuminate. Press the appropriate numbered button s of the zone s to be included or excluded. Page Technical Specification 4. Page Fuses Technical Specification 4. Page European Standards! Page Warranty details on request.

    Send to a friend

    As the Veritas is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Veritas failed to function correctly. Page Registered Installer Application Form Fax back to or post to the address overleaf. Registration available to UK Professional Installers only. This manual is also suitable for: Veritas 8compact Veritas r8.

    Windows 7 build 7601 activation key crack

    Comments to this Manuals Your Name:. Enter text from picture:. Latest comments:. Print page 1 Print document 44 pages. Cancel Delete.

    Veritas R8

    Sign in OR. Don't have an account? Sign up! Restore password.